Point & Extended Sources

Plane / Disk Source (Spills & Walls)

Evaluates dose rates above circularly distributed floor spills, sumps, or contaminated walls across contact, transition, and far-field elevation zones.

d ≤ 0.1R: I₀ | 0.1R–0.7R: I₀/3 | d > 0.7R: (I₀/3)(0.7R/d)²
Example Scenarios:

Input Parameters

Calculation Goal Guided Mode
Area Radius & Elevation Presets Zone 3 (>0.7R)
Convert Rectangular Spill Area to Effective Radius (R = √(L×W / π))
Plane / Disk Source (Spills & Walls) Parameters

Calculated Result & Visual Analysis

Nominal
Solved Value Updated automatically
--
--
Enter parameters on the left to calculate.
Geometry & Field Diagram Interactive Model
Sensitivity Curve

Governing Equation & Parameters

Zone 1 (≤0.1R): Constant I₀; Zone 2 (0.1R–0.7R): I₀ / 3; Zone 3 (>0.7R): (I₀ / 3) × (0.7R / d)²
Symbol Parameter Default Unit Definition
R cm Radius of the circular contamination area or tank face.
I₁ R Measured exposure rate at initial distance D₁ from the surface.
D₁ cm Initial perpendicular distance from the center of the contaminated area.
I₂ R Calculated exposure rate at target distance D₂.
D₂ cm Target worker elevation or standoff distance from the surface.

Health Physics Notes & Related Calculators

Operational Guidance

  • Contact Zone (d ≤ 0.1R): The contaminated surface subtends nearly 2π steradians; dose rate remains effectively constant with height.
  • Transition Zone (0.1R < d ≤ 0.7R): Dose rate steps down to approximately one-third of the contact reading.
  • Far-Field Zone (d > 0.7R): Dose rate follows inverse-square drop-off anchored at 0.7R.
  • For rectangular spills of length L and width W, use the effective circular radius R_eff = √(L × W / π).